Cable import data reference
Use this reference when preparing cable data for import.
General rules
- One row represents one cable.
- Cable distances are entered in metres.
- Coordinates should use decimal degrees.
- Referenced assets must already exist in the case.
- Asset and substation names should match the names used in the case.
- Use unique identifiers where possible.
- If a coordinate endpoint is used, provide both latitude and longitude.
Inter-array cables
Available import fields
| Field | Required | Example | Notes |
|---|---|---|---|
| Identifier | Optional | IAC-001 | Recommended for easier identification. |
| Wind farm equipment A | Conditional | WTG-01 | Existing asset at cable end A. |
| Wind farm equipment B | Conditional | WTG-02 | Existing asset at cable end B. |
| Cable A latitude | Conditional | 55.81234 | Used when end A is defined by coordinates. |
| Cable A longitude | Conditional | 6.12345 | Used with Cable A latitude. |
| Cable B latitude | Conditional | 55.81640 | Used when end B is defined by coordinates. |
| Cable B longitude | Conditional | 6.13760 | Used with Cable B latitude. |
| Cable distance | Optional | 1250 | Cable length in metres. |
| Completion date | Optional | 2026-06-15 | Include only when relevant. |
Valid endpoint combinations
Asset to asset -- provide:
- Wind farm equipment A
- Wind farm equipment B
Asset to coordinates -- provide:
- Wind farm equipment A
- Cable B latitude
- Cable B longitude
Or:
- Cable A latitude
- Cable A longitude
- Wind farm equipment B
Coordinates to coordinates -- provide:
- Cable A latitude
- Cable A longitude
- Cable B latitude
- Cable B longitude
Example
| Identifier | Wind farm equipment A | Wind farm equipment B | Cable A latitude | Cable A longitude | Cable B latitude | Cable B longitude | Cable distance |
|---|---|---|---|---|---|---|---|
| IAC-001 | WTG-01 | WTG-02 | 850 | ||||
| IAC-002 | WTG-02 | 55.81230 | 6.12540 | 1100 | |||
| IAC-003 | 55.80120 | 6.10110 | 55.80920 | 6.11830 | 1450 |
Export cables
Available import fields
| Field | Required | Example | Notes |
|---|---|---|---|
| Identifier | Optional | EXP-001 | Recommended for easier identification. |
| Substation | Required | OSS-01 | Must match an existing substation. |
| Latitude cable landing point | Required | 55.73421 | Landing-point latitude. |
| Longitude cable landing point | Required | 6.84210 | Landing-point longitude. |
| Cable distance | Optional | 42500 | Cable length in metres. |
| Completion date | Optional | 2026-08-01 | Include only when relevant. |
Example
| Identifier | Substation | Latitude cable landing point | Longitude cable landing point | Cable distance |
|---|---|---|---|---|
| EXP-001 | OSS-01 | 55.73421 | 6.84210 | 42500 |
| EXP-002 | OSS-02 | 55.69840 | 6.50120 | 38600 |
Cable distance
Cable distance is always entered in metres.
| Desired cable length | Enter |
|---|---|
| 850 m | 850 |
| 1.5 km | 1500 |
| 12 km | 12000 |
| 42.5 km | 42500 |
If a cable distance is not provided, it can be calculated automatically from the available endpoint locations.
Coordinate format
Use decimal degrees.
Correct:
55.734216.84210
Avoid including:
- degree symbols
- cardinal-direction letters
- coordinate labels inside the cell
For example, use 55.73421 rather than 55.73421° N.
Pre-import checklist
Before importing, confirm that:
- each row represents one cable
- referenced assets exist
- asset names match the case
- each cable has enough information to determine both endpoints
- latitude and longitude are numeric
- coordinate pairs are complete
- cable distance uses metres
- identifiers are unique where possible
- blank optional fields are left empty rather than filled with placeholder text
Troubleshooting
Referenced asset not found
Check spelling, spaces, and naming. The spreadsheet value should match the existing asset name.
Cable is missing after import
Check that both endpoints have valid locations.
For an inter-array cable, each endpoint needs either:
- an existing asset, or
- both latitude and longitude.
Invalid landing point
For an export cable, both landing-point latitude and longitude are required.
Cable is much longer or shorter than expected
Check the unit used for Cable distance. The value must be in metres.
Coordinates appear in the wrong place
Check whether latitude and longitude were accidentally reversed.